WHAT is the Strength of In-Place Concrete?
Concrete structures are designed to carry dead and live loads during construction and in service. Samples of concrete are obtained during construction and standard ASTM procedures are used to measure the potential strength of the concrete as delivered. Cylinders are molded and cured at 60 to 80°F (17 to 27°C) for one day and then moist cured in the laboratory until broken in compression, normally at an age of 7 and 28 days or at an alternative specified age.
The in-place strength of concrete will not be equivalent to that measured on standard cylinders and will generally be lower. Job practices for handling, placing, consolidation, and curing concrete in structures are relied upon to provide an adequate percentage of that potential strength, measured on cylinders, in the structure. Structural design principles recognize this and the ACI Building Code, ACI 318, has a process of assuring the structural safety during construction. In cold weather, a slower rate of in-place strength gain can be expected.
Means of measuring, estimating, or comparing the strength of in-place concrete include: rebound hammer, penetration probe, pullouts, maturity, cast-in- place cylinders, tests of drilled cores, and load tests of the structural member or system.
Cores drilled from the structure is one of the methods of evaluating whether the structural capacity of a concrete member is adequate. Drilled cores generally test lower than standard-cured cylinders. The ACI Building Code (ACI 318) recognizes that concrete construction can be considered structurally adequate if the average of three cores from a region represented by non-compliant concrete strength tests is equal to or exceeds 85 percent of specified strength, ƒ´c with no single core less than 75 percent of ƒ´c. Measured core strengths are not corrected for age. TIP 11 discusses core testing for acceptance of concrete. ACI 214.4R provides detailed guidance on core testing, evaluating existing structure capacity using in-place strengths, and determining an equivalent ƒ´c value for evaluating the structural capacity of an existing structure. The latter process should not be used to determine the acceptability of concrete furnished to a project.