Compressive strength results are used to ensure that the concrete mixture as delivered meets the requirements of the specified strength, ƒ´c, in the job specification.
Strength test results from cast cylinders may be used for quality control, acceptance of concrete, for estimating the strength in a structure, or for evaluating the adequacy of curing and protection afforded to the structure. Standard-cured cylinders are tested for acceptance and quality control. Field-cured cylinders are tested for estimating the in-place concrete strength. Procedures for standard-curing and field-curing are described in ASTM C31. Cylindrical specimens are tested in accordance with ASTM C39. Standard sizes of test specimens are 4×8 in. (100×200 mm) or 6×12 in. (150×300 mm) concrete cylinders. The smaller specimens tend to be easier to make and handle in the field and the laboratory.
A strength test result is the average of at least two strength specimens made from the same concrete sample and tested at the same age. In most cases strength requirements for concrete are at an age of 28 days.
Design engineers use the specified strength ƒ´c to design concrete members. The specified strength is stated in project specifications. The concrete mixture is designed to produce an average strength, ƒ´cr, higher than the specified strength so that the possibility of strength tests failing the acceptance criteria is very low. Historical strength test records from a similar concrete are used to establish the target average strength of concrete mixtures. TIP 2 discusses the process of establishing the required average strength for concrete mixtures.
To comply with the strength requirements of a specification, both the following acceptance criteria apply:
The same strength acceptance criteria are applicable for either cylinder size. It is important to understand that an individual test falling below ƒ´c does not constitute non-compliance with the strength acceptance criteria. The probability of not complying with these acceptance criteria is about 1% and that for an individual strength tests to be less than the specified strength is about 10%. This is based on the assumption that the average of strength tests are around the required average strength, ƒ´c, at the same level of variability of the assumed standard deviation
When strength test results indicate that the concrete delivered fails to comply with the acceptance criteria, it is possible that the failure may be in the testing, and not the concrete. This is especially true if the fabrication, handling, curing and testing of the cylinders are not conducted in accordance with standard procedures. See CIP 9 – Low Concrete Cylinder Strength.