Mass concrete
The main factor that defines a mass concrete member is its minimum dimension. ACI 301 suggests that a concrete member with a minimum dimension of 4 feet (1.3 m) should be considered as mass concrete. Some specifications use a volume-to-surface ratio. Other factors where precautions for mass concrete should be taken even for thinner sections are with higher heat generating concrete mixtures – higher cementitious materials content or faster hydrating mixtures.
The main concern with mass concrete is a high thermal surface gradient and resulting restraint as discussed above. These conditions can result during the initial stages due to heat of hydration and during the later stages due to ambient temperature changes. Another factor is a temperature differential between a mass concrete member and adjoining elements. As the mass member cools from its peak temperature, the contraction is restrained by the element it is attached to, resulting in cracking. Examples are thick walls or dams restrained by the foundation.